Research: Numerical analysis of restrained steel columns in fire


Steel columns are most likely to expand vertically when subjected to fire, resulting in an increase in internal force within the steel column. Due to material degradation in a fire, the column will buckle and fail quickly.

However, previous research on the restraining influence of connected elements on steel columns has primarily focused on the point at which the column’s internal force returns to its initial value [1]. Research of this nature has primarily explored the structural fire performance of restrained columns during the expansion phase while neglecting their performance during contraction. However, structural stiffness plays a significant role in limiting the vertical deflection of the column during contraction, as demonstrated in experimental research conducted at Tongji University [2]. Therefore, this study aims to comprehensively investigate the performance of restrained columns in fire. The objective of this study is to fully examine the performance of both continuous and non-continuous restrained columns in a fire.

For non-continuous steel columns, we used a 3m-long 310UC158 column as a case study. The time-axial deformation curve is presented in Figure 1 (a). The column expanded with heating until it reached buckling at point C1, after which the internal force along the column dropped to the applied load value at point C2, and it eventually failed at point C3. The deformation shape is depicted in Figure 1 (b) and (c). It’s evident that the column only reached its plastic deformation at C2 and was still far from its ultimate limit stage, as shown in Figure 1 (c).

Deflection-temperature-curve
(a) Deflection-temperature curve;
Plastic-deformation-at-P0=P
(b) Plastic deformation at P0=P;
Plastic-deformation-at-deflection-limit
(c) Plastic deformation at deflection limit_
Figure 1. Simulation results of steel column 3m in length.

 

In engineering practice, the load from a steel beam may induce a bending moment at the center of the column. The effect of this eccentric loading condition was considered in a case study of a 6m continuous steel column (310UC158), as shown in Figure 2. However, the simulation results indicated that the lateral moment from the connected beam has a negligible impact on the fire resistance of continuous steel columns.[/vc_column_text]

 

Loading condition of a continuous steel column in engineering practice
Figure 2. Loading condition of a continuous steel column in engineering practice

 

The case study conducted in this research, using ABAQUS, suggests that the restraint effect has a negligible impact on the fire resistance of continuous steel columns, but it is more evident for non-continuous steel columns. The eccentric loading condition made only a limited difference to the fire resistance of steel columns. Additionally, the comparison indicates that the current design approach in EN 1993-1-2 is slightly conservative when predicting the column’s limiting temperature.

 

Reference:
[1] Huang, Z.-F. and K.-H. Tan, Structural response of restrained steel columns at elevated temperatures. Part 2: FE simulation with focus on experimental secondary effects. Engineering structures, 2007. 29(9): p. 2036-2047.
[2] Jiang, B., et al., Experimental studies on progressive collapse resistance of steel moment frames under localized furnace loading. Journal of Structural Engineering, 2018. 144(2): p. 04017190.

Contributions to this article made by Fanqin Meng.


Author

  • Kaveh Andisheh

    Kaveh Andisheh

    GM Structural Systems

    Visit profile : Kaveh Andisheh


←Previous: Resource: Cold forming of steel before galvanising – what to consider
Next: Event: Residual stresses and defects webinar→

Follow our newsletter

Stay in the loop with our regular newsletter. Straight from our intellectual smelter, each issue contains plenty of education, inspiration, and connecting to what is important to our industry!

Subscribe


Industry awards

Our structure & governance

Our history

HERA Foundation

Venue hire

HERA House 
17 – 19 Gladding Place
Manukau City
Auckland


P O Box 76134
Manukau, Auckland 2241
New Zealand


Waeaatia (Call us):

+64 9 262 2885


General email enquiries:

info@hera.org.nz

Structural enquiries:

structural@hera.org.nz

Fabrication enquiries:

welding@hera.org.nz


@Copyright HERA 2024

Terms and conditions

Use of AI

Privacy policy

Refunds and returns

Site by Glue